Made in USA
Temptek 2 Ton Chiller – Model CG-2A
Features
Refrigerant Circuit
- R410A refrigerant
– Non-Ozone depleting
– Low global warming impact - Scroll Compressor
- Air-cooled condenser with finned tubes
- Refrigerant sight glass with moisture indicator
- Filter-drier
- Thermostatic expansion valve
- Hot gas bypass down to 50% capacity
- Brazed plate evaporator
- Liquid line solenoid valve
Coolant Circuit
- Insulated non-ferrous reservoir
(tank lid is standard on this model) - Reservoir level sight glass
- High flow centrifugal pump
- Standard NPT process fittings
Pressure Gauges
- Refrigerant high pressure
- Refrigerant low pressure
- Coolant pressure
Electrical
- Nema 1 control cabinet
- Process pump motor starter
- Compressor contactor
- Factory installed 10′ power cord
- Power entry terminal block
- Branch circuit fusing
System Limit Devices
- High refrigerant pressure
- Low refrigerant pressure
- Process pump motor overload
Frame Construction
- Powder coated steel cabinetry
- Galvanized steel cross frame
- Lift-off side panels
- Casters for portability
- Designed for indoor installation
Warranty
- 1 year covering parts and labor
Specifications
Model CG-2A
Capacity
- Tons : 2
- kW : 7.0
Compressor
- HP : 2
- Type : Scroll
Process Pump
- HP : 3/4
- GPM : 4.8
- PSI : 32
- Type : Centrifugal
- Construction : Stainless Steel
- Automatic Low Flow Bypass : Standard
Air-Cooled Condenser
- Type : Fan
- CFM : 2000
- (3) Ambient : 95°F
Refrigerant
- Type : R-410A
Full Load Amperage
- 230/3/60 : 17
- 460/3/60 : 8.5
Reservoir Capacity
- Holding : 7.5 gal
- Lid : Standard
- Auto Make-Up : Optional
Process Connections
- To Process : 3/4″
- From Process : 3/4″
Dimensions
- Height : 30″
- Width : 37″
- Depth : 24″
Weight
- Shipping :415 lbs
Specification Notes:
- 1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
- 2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ ” 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
- 3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
- 4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
- 5. Approximate unit weight crated for shipment.
CG Series Control
- Graphic LCD Display with Intuitive Navigation
- Digital Refrigerant Pressure Display
- Digital Water Pressure Display
- Plain Language Error Message Reporting
- Controls Hot Gas Bypass for Capacity Control
- Alarm Output with Audible Signal
- Industry 4.0 Ready Modbus RTU included – TCP optional
- High Water Temperature Shut Down
Options
Call or email for complete list of options pricing
Refrigerant Circuit
- Air Inlet filter and protection screen
Electrical
- UL listed electrical sub panel
Coolant Circuit
- Overhead Piping Kit
- Reverse Flow … gravity return to open tank
- Process Line Shut Off Valves
- Larger process pumps
Warranty
- Extended Compressor Warranty
Options Pricing | |
---|---|
Description | Price |
Audible Alarm | $170 |
Beacon Alarm | $685 |
Condenser Screen | $155 |
Overhead Piping Kit | $285 |
Reverse Flow Circuit | $100 |
Automatic Water Make-Up | $220 |
Process Shut-Off Valves | $90 |
Compressor Warranty | $175 |