Made in USA
Temptek 1 Ton Chiller – Model CF-1A
Features
Refrigerant Circuit
- HFC-134A refrigerant
– Non-Ozone depleting
– Low global warming impact - Hermetic Compressor
- Air-cooled condenser with finned tubes
- Propeller fan(s) induced air flow
- Refrigerant sight glass with moisture indicator
- Filter-drier
- Thermostatic expansion valve
Coolant Circuit
- Insulated non-ferrous reservoir
(tank lid is standard on this model) - Reservoir level sight glass
- Positive displacement pump
- Standard NPT process fittings
Electrical
- Nema 1 control cabinet
- Process pump motor starter
- Compressor contactor
- Factory installed 10′ power cord
System Limit Devices
- High refrigerant pressure
- Low refrigerant pressure
- Process pump motor overload
Frame Construction
- Stainless steel sheet metal
- Lift-off top cover panel
- Compact physical size
- Casters for portability
- Designed for indoor installation
Warranty
- 1 year covering parts and labor
MODEL CF-1A
(230/1/60)
$6,195
Specifications
Model CF-1A
Capacity
- Tons : 1
- kW : 3.5
Compressor
- HP : 1
- Type : Hermetic Reciprocating
Process Pump
- HP : 1/2
- GPM : 2.4
- PSI : 60
- Type : Positive Displacement
- Construction : Brass
- Automatic Low Flow Bypass: : Standard
Air-Cooled Condenser
- Type : Fan
- CFM : 7100
- (3) Ambient : 90°F
Refrigerant
- Type : R-134A
Full Load Amperage
- 230/1/60 : 15
Reservoir Capacity
- Holding : 4 gal
- Lid : Standard
- Auto Make-Up : Optional
Process Connections
- To Process : 1/2″
- From Process : 1/2″
- Make-Up : 1/2″
Dimensions
- Height : 37″
- Width : 19″
- Depth : 25″
Weight
- Shipping : 345 lbs
Specification Notes:
- 1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
- 2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ ” 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
- 3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
- 4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
- 5. Approximate unit weight crated for shipment.
CF Series Control
- Continuous To Process temperature display
- Selectable Setpoint temperature display
- Illuminated On / Off power switch
- Bright, easy-to-read LED temperature display window
- Basic chiller diagnostics with Refrigeration Fault light
- Refrigeration Fault light
- Machine Status with Compressor and Capacity Control indicating lights
Options
Call or email for complete list of options pricing
Refrigerant Circuit
- Air Inlet filter and protection screen
- Compressor CPR Valve (Setpoints above 65°F
Pressure Gauges
- Refrigerant High Pressure
- Refrigerant Low Pressure
- Coolant Pressure
Electrical
- UL listed electrical sub panel
Coolant Circuit
- Overhead Piping Kit
- Reverse Flow … Gravity Return to Open Tank
- Process Line Shut Off Valves
- Reservoir Water Make-Up Valve
Warranty
- Extended Compressor Warranty
Frame Construction
- Enclosure Panels
Options Pricing 1T and 1.5 T | |
---|---|
Description | Price |
Enclosure Panels & Condenser Screen | $500 |
Condenser Screen | $155 |
Overhead Piping Kit | $225 |
Reverse Flow Circuit | $100 |
CCPR Valve | $160 |
Automatic Water Make-Up | $185 |
Process Shut-Off Valves | $90 |
Refrigerant Pressure Gauges | $115 |
Hot Gas Bypass | $160 |